Floor Load Table

Type B Floor Deck 33ksi Load Table - Wide Flange Down

Uniform Total Load in Pounds Per Square Foot (Dead and Live)
Ga Span 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10
22
.0295
1 Stress 105 87 73 62 54 47 41 36 33 29 26
Deflection L/240 82 65 54 45 38 33 29 26 24 22
L/180 41 36 32 29 26
2 Stress 100 83 70 59 51 45 39 35 31 28 25
3 Stress 124 103 87 74 64 56 49 44 39 35 32
20
.0358
1 Stress 129 107 90 76 66 57 50 45 40 36 32
Deflection L/240 127 98 78 63 53 45 39 34 30 27 25
L/180 56 48 42 37 33 30
2 Stress 123 102 86 73 63 55 49 43 38 35 31
3 Stress 153 127 107 91 79 69 61 54 48 43 39
Deflection L/240 48 42 38
18
.0474
1 Stress 173 143 120 102 88 77 67 60 53 48 43
Deflection L/240 165 127 100 81 67 56 48 42 37 33 29
L/180 85 71 61 52 46 40 36
2 Stress 166 138 116 99 86 75 66 58 52 47 42
3 Stress 206 171 144 123 107 93 82 73 65 58 53
Deflection L/240 82 70 60 53 47
16
.0600
1 Stress 218 180 151 129 111 97 85 75 67 60 54
Deflection L/240 207 158 124 100 82 68 58 50 44 39 35
L/180 106 88 74 63 55 48 43
2 Stress 213 177 149 127 110 96 84 75 67 60 54
3 Stress 264 219 185 158 137 119 105 93 83 75 67
Deflection L/240 101 86 74 64 57

NOTES:
1. Load tables are calculated using section properties based on the steel design thickness shown in the Steel Deck Institute (SDI) design manual.
2. A dead load of 10 psf has been included for deflection only.
3. Contact Flexospan for maximum allowable unshored construction clear spans.
4. Contact Flexospan for spans greater than 10′

Contact your design professional for proper use of Flexospan load tables